The probe -oriented function can greatly reduce the detection workload, but in use, sometimes it feels that the probe orientation becomes unlimited and not flexible. What should I do at this time? Today, the editor of Weishi will answer it for you.
What is endoscopic probe orientation?
Observe the front end of the endoscopic probe, you will see a part that can be flexibly bent, usually called guided joints, just like the joints of our human beings, are the hubs that rotate in different directions. The probe -oriented joints are bent in different directions such as horizontal and vertical, which will drive different steers at the end of the probe. The view of the front -end lens will be adjusted to different directions, so that detectors can see detection images in different areas.
Why is the probe orientation not flexible?
In the guide channel of the probe line, the traction steel wire and other cables are accommodated, but the diameter of the general probe is only a few millimeters, so the traction steel wire and other cables are very close. In order to reduce the friction during the guidance operation, the guidance is smoother. Generally, it will use substances similar to lubricating powder in the guidance channel to keep the smooth contact between the metal wire and the metal wire and the channel. However, over time, long -term use may cause carbon powder to accumulate, resulting in uncomfortable orientation of industrial endoscope probes.
How to solve?
In this case, we can try to shake the probe gently. The glittering probe can restore the lubricating powder to be evenly distributed, so that the probe is flexible. The jitter probe usually requires two people to cooperate. One person holds the bottom below the guidance joint. Do not squeeze the guidance joint, because the guide joints are relatively soft, and the artificial force to make it bend may reduce the equipment -oriented life.
If the jitter probe does not improve the problem, it is recommended that you check whether the probe line is squeezed or damaged, and contact the manufacturer to seek solutions.
The above is the uncomfortable solution to the industrial endoscope probe. Thank you for your continuous attention to Shenzhen Weishi Optoelectronics Technology Co., Ltd.